TRACE Atomic Absorption Spectrometers

PRODUCT INFORMATION


    Dependable, Durable, and Complete Solutions for Atomic Absorption Spectrometry

    Aurora’s TRACE series of Atomic Absorption Spectrometers is the cornerstone of elemental analysis.

    The TRACE AI1200P provides complete solutions to accurately determine the peaks of 70+ elements, the widest analysis range on the market.

    The TRACE AI 1800 with dual flame (F) and graphite furnace (GF) atomizer, autosampler, and micro-volume flame analysis technology provide unparalleled throughput and sub ppb detection.

    With the previously mentioned features and the ability to include vapor-hydride generation (VG) capabilities to enable near-sub-ppb detection of certain elements, Aurora’s TRACE series of Atomic Absorbance Spectrometers can be configured to meet all of your elemental analysis requirements.

    AI1200plus-Front-Reflection 4x5-crop

    TRACE AI 1200P

    • F, F/GF, F/VG, F/GF/VG Atomizer Configurations
    • Czerny-Turner mounted optics with 1800 line/mm grating
    • Aberration corrected 300 mm Focus Length
    • 8 Lamp Turret
    • Optional Autosampler
    • Optional GF Video Monitor
    AI-1800-new-reflection 16x9

    TRACE AI 1800

    • F/GF, F/GF/VG Atomizer Configurations
    • Czerny-Turner mounted optics with 1800 line/mm grating
    • 8 Lamp 2-D Motorized Array
    • Integrate Autosampler
    • Integrated GF Video Monitor
    • Patented Micro Volume Flame Analysis, as low as 20 µl dispensing

    Features and Benefits

    Unrivalled elemental analysis potential: Each instrument can be equipped with flame ionization, graphite furnace ionization, and vapor-hydride generation capabilities; coupled with 70+ different lamp options, our AAS instruments provide unparalleled elemental analysis options.

    Automatic switching between atomizer layouts: Software-controlled atomizer configurations remove the need for manual intervention, giving you complete ease of use.

    Unparalleled background correction: Utilizing both deuterium and Smith-Hieftje background correction provides increased analytical efficiency and appreciable time reductions in your analysis procedures. The 1000 Hz modulation frequency further enables accurate corrections.

    Quick and easy lamp upkeep: The lamps are easily accessible for simple adjustments and replacements, removing the need to completely disassemble the instrument.

    Unrestricted throughput: The optional (AI1200P) or included (AI 1800) autosampler is compatible with all types of labware on the market, giving you the confidence to stick with your tried and tested analysis procedures.

    Innovation

    Atomic Absorption Spectrometer, GF testing graph for Cd.

    Background interferences: The TRACE Series comes complete with background correction techniques: Deuterium and Smith-Hieftje.

    TRACE Atomic Absorption Spectrometers, Calibration Curve Online Dilution

    Online Dilution: Create a working calibration curve from a single standard sample. No need to manually prepare a standard dilution series.

    Atomic Absorption Spectrometer, TRACE AI 1800, F/GF, F/GF/VG Atomizer Configurations Czerny-Turner mounted optics with 1800 line/mm grating 8 Lamp 2-D Motorized Array Integrate Autosampler Integrated GF Video Monitor Patented Micro Volume Flame Analysis, as low as 20 µl dispensing for flame ionization

    Autosampler: As one of the most versatile autosamplers on the market, compatible with all types of third-party labware, you benefit from the complete comfort of being able to use nearly any size of vial or sample holder. Save staff time, reduce human error, and increase sample reproducibility.

    Atomic absorbance spectrometer spectrometry instrument graphite furnace technology elemental analysis

    Fast Dry Technology: Coupled with the auto-sampler, this allows for a single-sample processing time of under 30 seconds. With further adjustments of preheating and cooling temperatures, as well as injection speeds, drying times are further decreased.

    Atomic Absorption Spectrometry (AAS), also called Atomic Emission Spectroscopy (AES), is a tried-and-tested elemental analysis technique. The instruments themselves are called atomic absorption spectrophotometers. By using a combination of an atomizing unit (to generate gaseous-phase atoms that emit light) and a spectrophotometer (to measure the intensity of light emitted from the aforementioned atoms), certain elements can be detected and quantified down to parts-per-billion and parts-per-trillion concentrations.